Keratron™ Scout: precise, accurate, modular, portable

This corneal topographer is aimed at those users who want a compact and portable instrument.

software & instructions

Main functions:

  • Wide coverage corneal topography
  • Corneal aberrometry
  • Pupillometry
  • Non-invasive break-up time

Thanks to the completeness of options, this topographer can adapt to the different needs of the user.

Its small size allows maximum compatibility on any slit lamp.

The instrument becomes portable, inserting a special power supply module at the base and, thanks to the headrest device and the repeatability control, it allows easy acquisition and maximum reliability measurements.

The Keratron ™ Scout, thanks to its integrated display, allows full control during the image acquisition process and a quick transfer of the same to a PC.

Keratron

parameter specifications
MODEL Keratron™ Scout

CONFIGURATIONS

Portable battery or cable operated
Slit lamp easily mounted on any slit lamp

VIDEOKERATOSCOPE

Area of analysis 10 mm x 14 mm (visible on the monitor)
Keratoscope cone 28 border mires, equally spaced on a 43D sphere
Analysed points over 80,000
Measured points 7,168
Corneal coverage from 0.33 mm (minimum diameter on a 43D sphere) up to 11mm on a normal eye
Measured area 90% of the corneal surface (normal eyes)
Dioptric power range from 1D to over 120D
Resolution +/- 0.01D, 1 micron
Focusing device Eye Positioning Control System EPCS (patented) automatic acquisition, with decentration correction
TV camera high resolution (C.C.I.R.)
Monitor 2,5”
Other features “OK” button and OD/OS acquisition keys, low-power standby function, tiltable mires cone (0°-10°)
Weight 1 Kg approx.
Accessories included calibration set, Scout software

COMPUTER (RECOMMENDED MINIMAL FEATURES)

Operating system MS Windows 7/8/10 (32 e 64 bit)
Processor/Memory Intel I3, 2GB RAM
Disks Internal 180 GB HD, CD-ROM
Monitor Super VGA color monitor 14″, 1024×768 points 16 millions color
Printer Color printer
Port Ethernet, USB 2.0 High speed

SOFTWARE

Dioptric scale Absolute, Normalized, Adjustable
Keratometric values and indices K-readings, Meridians, Hemimeridians, Maloney Indices, Eccentricity
Pupil border detection, diameter and decentration
Zones and grids 3, 5 and 7 mm, orthogonal axis or millimeter grid
Maps Local curvature, axial curvature, wavefront OPD or Wfe refraction map with 3D insert
Move axis position of the axis selectable as corneal vertex, pupil center or any other choice
Print print screen with header of the institution, or personalized print templates
Special functiones profiles, difference, repeatability check, maps comparison, caliper, refraction calculator
Image acquisition enabled with TV camera mounted on a slit lamp and video capture board (not included)
On-line help on-line multi-language help detailed for all functions
Contact lens fluorescein pattern simulation of most of international contact lens manufacturers’ geometries
tilting to simulate lid pressure
lens displacement in any position
eccentricity measured at 6 and 8 mm, over-refraction calculator
personalized auto-fit for customized lens
adjustable clearance scale
link to third party software
Internet connection maps can be sent as attachments to e-mail messages
Local network and database management of one or more independent databases shareable in a network

ACCESSORIES

Docking base power supply for videokeratoscope, USB interface to the computer, battery charger
Slit lamp kit slit lamp attachment for tonometer hole D=8 mm, connection cable
Far mires cone for deep set eyes. 28 mires are 3 mm more recessed than standard cone
Battery charger normal (15h) or fast (2h)
Battery/Head rest module can be connected to videokeratoscope for hand held operation
battery 2100 mAh (1 hour)

REGULATORY

Regulatory Conformity 93/42/EEC Directive on medical devices
Technical standards: EN 60601-1:2006
EN 60601-1-2:2007+AC:2010
EN62471:2008
EN 62304:2006

ENVIRONMENTAL SPECIFICATIONS

Storage temperature range between -10°C and +60°C
humidity 0-100% (condensation included)
atmospheric pressure 500 to 1060 hPa
Operating temperature range between 0°C and +40°C
humidity 0-90% (non condensing)
atmosphere pressure 700 to 1060 hPa

ELECTRICAL SPECIFICATIONS

DOCKING BASE

Input voltage selectable at 100/120/220/230 Vac
Frequency 50/60 Hz
Power consumption 60 VA
Fuses 220/240 Volt: 1 A T
100/120 Volt: 2 A T

VIDEOKERATOSCOPE

Input voltage 14-18 Vdc supplied by the Docking Base or by the Battery
Power consumption 28 VA
KERATRON SCOUT PORTABLE WITH PUPILLOMETRY

162202 – Docking Base

162208 – Head Rest

162202 Docking Base

162206 Slit Lamp Adaptor Kit

162202 – Docking Base

162206 – Slit Lamp Adaptor Kit

162208 – Head Rest

162211 – ‘Far’ Mires Cone

162212 – Slit Lamp Adaptor Eccentric Spacer

163202 – Base with Joystick for Scout

169201 – Smart Case for Scout

196203 – Cover for Scout Far Cone (single-use, sterile, 6/box)

Compile the form or register to access this content.

Download Area

Filling out this form you will access to
  • Brochures
  • Presentations
  • User Manuals
... for all our products.


    Download Software & Instructions

    Access the Software area to download:
    • Software application & updates
    • Video Tutorials
    • Certificates
    • Instructions for Use
    ... for all our products.
    software & instructions