parameter specifications
MODEL | Keratron™ Piccolo |
---|
CONFIGURATIONS
Portable | easly mounted on any slit lamp |
---|
VIDEOKERATOSCOPE
Area of analysis | 10mm x 14 mm (visible on the monitor) |
---|---|
Keratoscope cone | 28 border mires, equally spaced on a 43D sphere |
Analysed points | over 80,000 |
Measured points | 7,168 |
Corneal coverage | from 0.33 mm (minimum diameter on a 43D sphere) up to 11mm on a normal eye |
Measured area | 90% of the corneal surface (normal eyes) |
Dioptric power range | +/-From 1 to over 120D |
Resolution | ± 0,01D – 1 micron |
Focusing device | Eye Positioning Control System EPCS (patented) automatic acquisition with decentration correction |
TVcamera | C.C.I.R. |
Other features | tiltable mires cone (0°-10°) |
Weight | 1 Kg approx. |
Accessories included | calibration set, Scout software |
COMPUTER (RECOMMENDED MINIMAL FEATURES)
Operating system | MS Windows 7/8/10 (32 e 64 bit) |
---|---|
Processor/Memory | Intel I3, 2GB RAM |
Disks | Internal 180 GB HD, CD-ROM |
Monitor | Super VGA color monitor 14″, 1024×768 points 16 millions color |
Printer | Color printer |
Port | USB 2.0 High speed |
SOFTWARE
Dioptric scale | Absolute, Normalized, Adjustable |
---|---|
Keratometric values and indices | K-readings, Meridians, Hemimeridians, Maloney Indices, Eccentricity, CLMI keratoconus indices |
Pupil | border detection, diameter and decentration |
Zones and grids | 3,5 and 7 mm, othogonal axis or millimeter grid |
Maps | local curvature, axial curvature, wavefront OPD or wavefront error (Wfe) refraction map with 3D insert |
Move axis | position of the axis selectable as corneal vertex, pupil center on any other choice |
print screen with header of the institution, or personalized print templates | |
Special functions | profiles, difference, repeatability check, maps comparison, caliper, refraction calculator |
Image acquisition and movies | enabled with TV camera mounted on a slit lamp and video capture board (not included) |
On-line help | on-line multi language help detailed for all functions |
Contact lens | fluorescein pattern simulation of most of international contact lens manufactures geometries tilting to simulate lid pressure lens displacement in any position eccentricity measured at 6 and 8 mm, over-refraction calculator personalized auto-fit for customized lens adjustable clearance scale link to third party software |
Internet connection | maps can be sent as attachments to e-mail messages |
Local network and database | management of one or more indipendent databases shareable in a network |
ACCESSORIES
Base | power supply for videokeratoscope, footswitch interface |
---|---|
Far mires come | for deep set eyes. 28 mires are 3mm more recessed than standard cone |
Base joystick | with table and chin rest |
REGULATORY
Regulatory conformity | Directive on medical devices 93/42/EEC |
---|---|
Technical standards: | EN 60601-1 EN 60601-1-1 EN 60601-1-2 |
ENVIRONMENTAL SPECIFICATIONS
Storage | temperature range between -10°C and +60°C humidity 0-100% (condensation included) atmospheric pressure from 500 to 1060 hPa |
---|---|
Operating | temp. range between 0°C and +40°C humidity 0-90% (non-condensing) atmospheric pressure from 700 to 1060 hPa |
ELECTRICAL SPECIFICATIONS
BASE
Input voltage | 90÷264 V AC |
---|---|
Frequency | 50/60 Hz |
Power consumption | 16VA |
Fuses | 100/240 Vac 3.15A TH |
KERATRON™ PICCOLO
Input voltage | 10-11 Vdc supplied by the Base |
---|---|
Power Consumption | 12 VA |